#TheBatteryShow
Venue: Atlanta, GA, USA
The 242nd ECS Meeting takes place in Atlanta, Georgia, from October 9 to October 13, 2022, at the Hilton Atlanta. This international conference brings together the most active professional and student researchers in academia, government, and industry to engage, discuss, and innovate in the areas of electrochemistry and solid state science and technology, and allied subjects. This is the premier destination for industry professionals to experience five days of learning, technical presentations, business development, and networking opportunities.
The topics of this meeting include
- Batteries and Energy Storage,
-Carbon Nanostructures and Devices,
-Corrosion Science and Technology,
-Dielectric Science and Materials,
-Electrochemical/Electroless Deposition,
-Electrochemical Engineering,
-Electronic Materials and Processing,
-Electronic and Photonic Devices and Systems,
-Fuel Cells, Electrolyzers, and Energy Conversion,
-Luminescence and Display Materials, Devices, and Processing,
-Organic and Bioelectrochemistry,
-Physical and Analytical Electrochemistry,
-Electrocatalysis, and Photoelectrochemistry,
-Sensors
NEWARE will participate in this conference and hope to communicate with you there!
NEWARE
47690 Westinghouse Dr, Fremont, CA 94539
● Voltage&Current Accuracy:±0.01% F.S.
● Recording Frequency:100Hz
● Current Response Time:≤1ms
● Minimum Pulse Width:500ms
● Off-Line Test:1GB/CH
● Cycle Life, GITT Test, DCIR Test, dQ/dV Curve
● Voltage & Current Accuracy:±0.01% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Minimum Pulse Width:500ms
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage Accuracy:±0.02% F.S.
● Current Accuracy:±0.05% F.S.
● Resolution Ratio AD/DA:16bit
● Current Response Time:≤1ms
● Minimum Pulse Width:100ms
● Off-Line Test:1GB/CH
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:100Hz
● Current Conversion Time:≤6ms
● Current Response Time:≤3ms
● Minimum Pulse Width:100ms
● Feedback Efficiency (Max) :75%
● Voltage & Current Accuracy:±0.02% F.S.
● Voltage & Current Stability:±0.01% F.S.
● Recording Frequency:1000Hz
● Resolution AD:16bit
● Current Response Time:≤100μs
● Off-Line Test: 1GB