Lithium-ion batteries, as the most mainstream rechargeable battery technology, have developed rapidly in recent years. The energy density and charging speed of new lithium-ion batteries continue to increase, and the cost continues to decline. At the same time, people have also turned part of their attention to improving battery life, safety and so on. Among them, estimating the state of charge ( SOC ) of the battery is one of the effective methods.
In recent years, there are many methods to estimate the SOC of lithium-ion batteries, such as traditional estimation methods, model-based estimation methods and data-driven estimation methods. However, each type of method still has shortcomings. Traditional estimation methods will have significant errors. The accuracy of the model-based estimation method is affected by the complexity of the model. The estimation method of data-driven method requires a lot of calculation. In order to simplify the steps of the estimation method and improve the accuracy of the estimation method, the development of a new method for estimating SOC has become a widespread research goal.
In order to estimate the state of charge of the battery more accurately, the accurate determination of the battery data set under different dynamic test conditions has become the key. Previous battery test equipment often has problems such as insufficient accuracy and slow dynamic data capture, and its application is seriously limited. At the same time, rough data acquisition also makes the calculation fitting encounter many problems.
Therefore, advanced test equipment with high precision has become a necessary choice.
In order to meet the various test requirements of researchers, NEWARE has launched a series of battery test equipments, including CT/CTE-4000 battery test equipments. Recently, NEWARE and Fan Xingming's team of Guilin University of Electronic Technology have reached a relevant cooperation. The team proposed a new fusion algorithm of adaptive genetic algorithm (AGA) optimized adaptive unscented Kalman filter (AUKF) to estimate the state of charge of the battery. In order to verify the accuracy of the algorithm estimation, the team chose to use NEWARE battery testing system (CT-4008Q-5V6A-S1) to complete the battery data acquisition under different conditions.
This series of test equipment adopts multi-range technology, which can achieve the purpose of fast output. By using the test instrument, the team obtained a series of accurate battery data sets, further revised the calculation method and successfully confirmed the feasibility of the calculation method.
After completing the research, the team also showed that ' this high-performance battery testing system provides accurate battery discharge test data and is an indispensable part of the paper.
The corrsponding literatures:https://doi.org/10.1016/j.est.2023.109689
NEWARE
755 Ames Avenue, Milpitas, CA, USA, 95035
● Voltage&Current Accuracy:±0.01% F.S.
● Recording Frequency:100Hz
● Current Response Time:≤1ms
● Minimum Pulse Width:500ms
● Off-Line Test:1GB/CH
● Cycle Life, GITT Test, DCIR Test, dQ/dV Curve
● Voltage & Current Accuracy:±0.01% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Minimum Pulse Width:500ms
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage Accuracy:±0.02% F.S.
● Current Accuracy:±0.05% F.S.
● Resolution Ratio AD/DA:16bit
● Current Response Time:≤1ms
● Minimum Pulse Width:100ms
● Off-Line Test:1GB/CH
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:100Hz
● Current Conversion Time:≤6ms
● Current Response Time:≤3ms
● Minimum Pulse Width:100ms
● Feedback Efficiency (Max) :75%
● Voltage & Current Accuracy:±0.02% F.S.
● Voltage & Current Stability:±0.01% F.S.
● Recording Frequency:1000Hz
● Resolution AD:16bit
● Current Response Time:≤100μs
● Off-Line Test: 1GB