Supports CAN FD 2Mbps high-speed transmission and RS485 long-distance communication, with 8 fully isolated channels for simultaneous battery module data acquisition. Precisely monitors critical parameters including voltage, temperature, and current, meeting the demands of high-frequency, high-precision monitoring in new energy vehicles, energy storage systems, and similar applications.
Built-in CANFDNET-200U protocol stack, compatible with mainstream software such as ZLG CANPRO. Features multi-TCP Server connections (up to 4 paths), customizable port configurations, IP binding, and seamless integration with BMS, thermal chamber monitoring systems, and other devices.
Achieves 8,000 frames/s CANFD transmit/receive capability per channel (total), combined with 16KB network cache + 200 CANFD message buffer. Ensures <20ms transmission latency for complete data integrity under extreme conditions, ideal for high-frequency pulse signals or burst data scenarios.
1.5kV electromagnetic isolation for network ports and signal paths. Operates reliably in -20°C to 50°C environments. Simplifies deployment with static IP configuration and web-based management interface, ensuring long-term stability in industrial settings with strong interference resistance.
Supports dual-mode switching (CANFD/CAN), configurable RS485 baud rates (9.6K–115.2Kbps), and independent arbitration field/data field speed adjustments (up to 5M/2M). Includes software/hardware upgrade interfaces to adapt to future battery technology advancements.
Equipment name | Power Battery DAQ Box |
---|---|
Channel Count | 8 channels |
Power Consumption | 15W |
Serial Interface | RS485 |
CAN FD Bit Rates | 125 K; 250 K; 500 K; 1 M; 2 M; 3 M; 4 M; 5 M bps |
CAN FD Throughput | 8,000 frames/sec per channel |
Storage Temperature | -20°C to 50°C |
Dimensions | 1U (19") 484×149×44 mm |
Weight | Approximately 2.2 kg |
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.01% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Minimum Pulse Width:500ms
● Off-Line Test: 1GB
● Voltage&Current Accuracy:±0.01% F.S.
● Recording Frequency:100Hz
● Current Response Time:≤1ms
● Minimum Pulse Width:500ms
● Off-Line Test:1GB/CH
● Cycle Life, GITT Test, DCIR Test, dQ/dV Curve
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:100Hz
● Temperature Fluctuation:≤1.8℉(1℃)
● Temperature Range & Deviation:-40℉ ~ 302℉±3.6℉(-40℃ ~ 150℃±2.0℃)
● Heating Efficiency:68℉ ~ 302℉ ≤60min(20℃ ~ 150℃)
● Cooling Efficiency:68℉ ~ -40℉≤60min(20℃~-40℃)
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:100Hz
● Number of Channels:80CH
● Temperature Range & Deviation:50℉ ~ 185℉±3.6℉(10℃ ~ 85℃±2.0℃)
● Heating Efficiency:77℉ ~ 185℉ ≤40min(25℃ ~ 85℃)
● Cooling Efficiency:77℉ ~ 50℉≤40min(25℃~10 ℃)
● Voltage & Current Accuracy:±0.01% F.S.
● Recording Frequency:100Hz
● Number of Channels:160CH
● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(0℃ ~ 60℃±2.0℃)
● Heating Efficiency:77℉ ~ 140℉ ≤30min(25℃ ~ 60℃)
● Cooling Efficiency:77℉ ~ 32℉≤50min(25℃~0 ℃)
● Voltage & Current Accuracy:±0.05% F.S.
● Sampling Time:100ms
● Number of Channels:16CH
● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(15℃ ~ 60℃±2.0℃)
● Heating Efficiency:77℉ ~ 140℉≤50min(25℃ ~ 60℃)
● Cooling Efficiency:77℉ ~ 59℉≤60min(25℃~15 ℃)