Features
Tech Specs
Resources
● High-voltage safety compliance testing: Supports insulation resistance (0.1MΩ–500GΩ) and DC/AC withstand voltage testing, ensuring battery systems meet international safety standards.
● Intelligent alarming and protection: Combines hardware-level overvoltage/overcurrent/overtemperature protection with software-programmable safety thresholds (voltage/current limits) for dual-layer risk mitigation.
● Failure mode simulation: Integrates short-circuit detection, HVIL (High Voltage Interlock) verification, and simulated collision signals to expose design flaws proactively.
● Integrated charge/discharge: Single-channel 40kW power with 0-200V/±200A range, covering full lifecycle testing of power batteries.
● Accurate resistance diagnostics: Dual-mode DCIR (±0.05% accuracy) and ACIR (3mΩ–300Ω range) measurements to rapidly identify cell inconsistencies.
● Dynamic performance validation: Current response time ≤3ms and minimum step duration 0.1s, compatible with fast-charging protocol validation and transient condition simulation.
● Full BMS functional verification: Supports CAN communication (DBC configuration), SOC calibration, cell balancing diagnostics, and fast/slow charge state simulation for BMS-battery system co-testing.
● Multi-dimensional data cdomparison: Automatically aligns BMS-reported data (voltage/temperature/voltage deviation) with device-measured values, visualizing accuracy deviations in real time.
● Customizable workflows: Define test parameters, items, and sequences flexibly.
● Data traceability: Supports TCP/IP communication and wireless barcode scanners (1D/2D codes) to automatically link test data with battery IDs.
● One-click reporting: Exports test results to Excel/TXT formats with automatic synchronization to MySQL databases.
● Multi-protocol support: CAN/CANFD, RS485, RS232, Line, LAN.
● MES integration: Compatible with custom MES systems via open APIs for secondary development.
● BMS universal compatibility: Built-in DBC converter for multi-standard BMS interfaces.
● Multi-device synergy: Controls environmental chambers, chillers, and auxiliary equipment for complex scenario simulations.
Equipment name | EOL Battery Testing System |
---|---|
Model | CE-6002-200V200A-EOL |
Charge/Discharge Testing | |
Voltage Range | 12V~200V |
Voltage Accuracy | ±0.02% F.S. |
Current Range | 0A~200A |
Current Accuracy | ±0.05% F.S. |
AC Impedance Meter | |
Range | 3mΩ–300Ω |
Accuracy | ±0.5% rdg ±10 dgt |
Resolution | 0.1μΩ |
Withstand Voltage Tester | |
DC | 0.05kV~6kV |
AC | 0.05kV~5kV |
Multimeter | |
DCV | 100mV~1000V |
Resolution | 6½ digits |
Insulation Resistance Simulator | |
Resistance Range | 50Ω~1000MΩ |
Resolution | ±50Ω |
I/O Communication | |
I/O | 4× CAN
4× 485 1× RS232 6× Activation Signals |
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.01% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Minimum Pulse Width:500ms
● Off-Line Test: 1GB
● Voltage&Current Accuracy:±0.01% F.S.
● Recording Frequency:100Hz
● Current Response Time:≤1ms
● Minimum Pulse Width:500ms
● Off-Line Test:1GB/CH
● Cycle Life, GITT Test, DCIR Test, dQ/dV Curve
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:100Hz
● Temperature Fluctuation:≤1.8℉(1℃)
● Temperature Range & Deviation:-40℉ ~ 302℉±3.6℉(-40℃ ~ 150℃±2.0℃)
● Heating Efficiency:68℉ ~ 302℉ ≤60min(20℃ ~ 150℃)
● Cooling Efficiency:68℉ ~ -40℉≤60min(20℃~-40℃)
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:100Hz
● Number of Channels:80CH
● Temperature Range & Deviation:50℉ ~ 185℉±3.6℉(10℃ ~ 85℃±2.0℃)
● Heating Efficiency:77℉ ~ 185℉ ≤40min(25℃ ~ 85℃)
● Cooling Efficiency:77℉ ~ 50℉≤40min(25℃~10 ℃)
● Voltage & Current Accuracy:±0.01% F.S.
● Recording Frequency:100Hz
● Number of Channels:160CH
● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(0℃ ~ 60℃±2.0℃)
● Heating Efficiency:77℉ ~ 140℉ ≤30min(25℃ ~ 60℃)
● Cooling Efficiency:77℉ ~ 32℉≤50min(25℃~0 ℃)
● Voltage & Current Accuracy:±0.05% F.S.
● Sampling Time:100ms
● Number of Channels:16CH
● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(15℃ ~ 60℃±2.0℃)
● Heating Efficiency:77℉ ~ 140℉≤50min(25℃ ~ 60℃)
● Cooling Efficiency:77℉ ~ 59℉≤60min(25℃~15 ℃)