Battery Test Equipment Different Series function and parameter comparison

Battery Test Equipment Different Series

Quickly understand the differences between NEWARE battery test equipment series.
Array
Array
CE-6000 Series NEWARE Battery Test,The world's top professional and advanced battery testing equipment
Array
Array

Application scenarios

● Battery materials research
● 3C products
● Power/energy storage cells (Power tools, Electric vehicles and etc.)
● Electric vehicles
● Communication base stations
● Energy storage and other battery pack
● Electric bus
● Large energy storage battery pack
● Power/energy storage cells (Power tools, Electric vehicles, Energy storage cells and etc.)
● Battery materials research
● 3C products
● Power/energy storage cells (Power tools, Electric vehicles and etc.)
● Battery materials research
● 3C battery research and etc.

Voltage ranges

5V / 6V / 10V / 20V
5V
5V / 6V / ... /
500V / ... / 1000V
5V / 10V / 20V /
24V / 30V
5V

Current ranges

10mA / ... / 100mA /
6A / 12A
100mA / 20A / 30A /
... / 500A / ... /
1500A
20A / 30A / 40A /
60A / ... / 600A /
... / 1200A
100mA / 10A / 15A /
... / 75A / ... /
1200A / ... / 7200A
5A / 6A / 6.5A /
12A / 13A

Resolution

AD: 16bit
DA: 16bit
AD: 16bit / 24bit
DA: 16bit
AD: 24bit
DA: 24bit
AD: 16bit
DA: 16bit
AD: 16bit
DA: 16bit

Display resolution

0.1mV / 0.1mA
0.1mV / 0.1mA
0.1mV / 0.1mA
0.1mV / 0.1mA
0.1mV / 0.1mA

Input impedance

≥1MΩ / ≥1GΩ / ≥100kΩ
≥100kΩ / ≥1MΩ
≥1MΩ
Main channel ≥ 1MΩ
Auxiliary channel ≥ 200kΩ / 1GΩ
≥1000MΩ Startup state (shutdown leakage current is 100 μA)

Energy feedback function (energy saving)

Supports: ≥65% (Full load)
Not support for linear power supply solution
Supports:
>75% (Full load)
>90% (Full load)
>94% (Full load)
Supports: ≥80% (Full load)
Not support for linear power scheme

Power factor (PF)

≥99% (Full load)
≥99% (Full load)
≥99% (Full load)
≥99% (Full load)
≥99% (Full load)

Lowest discharge voltage

-5V / 0V / 1V /
1.5V / 2V / 2.5V
0V / 2.5V
-10V / 1.7V / 3V /
5V / 10V / 30V
-5V / -3V / 0V /
1.5V / 2.5V
-5V / 0.7V

Voltage accuracy

± 0.01% F.S.
± 0.02% F.S.
± 0.05% F.S.
± 0.1% F.S.
± 0.01% F.S.
± 0.02% F.S.
± 0.05% F.S.
± 0.01% F.S.
± 0.02% F.S.
± 0.05% F.S.
± 0.02% F.S.
± 0.02% F.S.

Voltage stability

± 0.01% F.S.
± 0.02% F.S.
± 0.05% F.S.
± 0.1% F.S.
± 0.01% F.S.
± 0.02% F.S.
± 0.05% F.S.
± 0.01% F.S.
± 0.05% F.S.
± 0.01% F.S.
± 0.01% F.S.

Current range segmentation

Single range
Three ranges
Four ranges
Three ranges
Four ranges
Single range
Single range
Three ranges
Four ranges
Multi-ranges
Four ranges

Current accuracy

± 0.02% F.S.
± 0.05% F.S.
± 0.1% F.S.
± 0.02% F.S.
± 0.05% F.S.
± 0.05% F.S.
± 0.02% F.S.
± 0.03% F.S.
± 0.05% F.S.
± 0.02% F.S.

Constant voltage cut-off current

Each independent range* 0.2%
Each independent range* 0.2%
Each independent range* 0.1%

Current stability

± 0.02% F.S.
± 0.05% F.S.
± 0.1% F.S.
± 0.02% F.S.
± 0.05% F.S.
± 0.05% F.S.
± 0.025% F.S.
± 0.01% F.S.
± 0.015% F.S.
± 0.025% F.S.
± 0.01% F.S.

Single-channel maximum power

Voltage * Current
Voltage * Current
Voltage * Current
Voltage * Current
Voltage * Current

Power stability

± 0.03% F.S.
± 0.5% F.S.
± 0.1% F.S.
± 0.1% F.S.
± 0.05% F.S.
± 0.02% F.S.
± 0.05% F.S.
± 0.01% F.S.

Current response time

≤20ms / ≤500μs / ≤1ms
≤5ms / ≤10ms
≤3ms / ≤5ms
≤20ms / ≤30ms / ≤1ms
≤100μs

Charging and discharge conversion time

≤40ms / ≤25ms
≤20ms
≤6ms / ≤10ms
≤20ms / ≤30ms / ≤2ms
35ms

Record frequency

100ms (10Hz)
10ms (100Hz)
10ms (100Hz)
The auxiliary channel is 10Hz
10ms (100Hz)
1ms (1000Hz)

Minimum voltage interval

Voltage range * 0.2%
Voltage range * 0.2%
Voltage range * 0.2%
Voltage range * 0.2%

Minimum current interval

Each independent current range * 0.2%
Each independent current range * 0.2%
Each independent current range * 0.2%

Charge and discharge mode

● Constant current charge and discharge
● Constant voltage charge and discharge
● Constant current constant voltage charge and discharge
● Constant power charge and discharge
● Pulse charge and discharge
● Constant resistance charge and discharge
● Follow mode charge and discharge and etc.
● Constant current charge and discharge
● Constant voltage charge and discharge
● Constant current constant voltage charge and discharge
● Constant power charge and discharge
● Pulse charge and discharge
● Constant resistance charge and discharge
● Follow mode charge and discharge and etc.
● Constant current charge and discharge
● Constant voltage charge and discharge
● Constant current constant voltage charge and discharge
● Constant power charge and discharge
● Pulse charge and discharge
● Constant resistance charge and discharge
● Follow mode charge and discharge and etc.
● Constant current charge and discharge
● Constant voltage charge
● Constant current constant voltage charge and discharge
● Constant power charge and discharge
● Constant power constant voltage charge and discharge
● Pulse charge and discharge
● Constant resistance discharge and etc.
● Constant current charge and discharge
● Constant voltage charge
● Constant current constant voltage charge and discharge
● Constant power charge and discharge
● Constant power constant voltage charge and discharge
● Pulse charge and discharge
● Constant resistance discharge and etc.

Cut-off condition

Voltage, Current, Relative time, Capacity, -△V and etc.
Voltage, Current, Relative time, Capacity, -△V and etc.
Voltage, Current, Relative time, Capacity, -△V and etc.
Voltage, Current, Relative time, Capacity, Energy, -△V, Custom variables, and etc.
Voltage, Current, Relative time, Capacity, Energy, -△V, Custom variables, and etc.

Pulse/condition function

Pulse
Pulse / Condition
Pulse / Condition
Condition
Pulse / Condition

Charge/discharge mode (pulse/condition)

Constant current mode
Constant power mode
Constant current mode
Constant power mode
Constant current mode
Constant power mode
Constant current mode
Constant power mode

Minimum Pulse Width (pulse/condition)

500ms
100ms / 500ms
100ms
400μs

Pulses numbers

A single pulse step supports 32 different pulses
A single pulse step supports 32 different pulses
A single pulse step supports 32 different pulses
A single pulse step supports 16 different pulse segments

Continuous switch of charge and discharge (pulse)

A pulse step can realize the continuous switch from charge to discharge
A pulse step can realize the continuous switch from charge to discharge
A pulse step can realize the continuous switch from charge to discharge
A pulse working step can realize continuous switching of charge, or continuous switching of discharge

Cut-off condition (pulse/condition)

Voltage, Relative time
Voltage, Relative time
Voltage, Relative time
Voltage, Number of pulses, Working time

Step file line limit

Do not support
Support
Support
Support
Support

DCIR test

Support
Support
Support
Support
Support

Channel bundling

Greater than 50A supports four-channel parallel connection
Supports a maximum of two adjacent channels in parallel
Parallel connection of up to 4 channels is supported.
Pulse and simulation tests are not supported after parallel connection
Energy saving devices of 75A and higher support parallel channels
Do not support

Loop setting ranges

65535
65535
65535
65535
65535

Loop nesting

≤3 layers
≤3 layers
≤3 layers
≤4 layers
≤4 layers

Edit the number of work steps in a single process

254
254
254
255
255

Software/hardware protection

● Power down data protection
● Offline testing
● Voltage upper/lower limits
● Current upper/lower limits
● Capacity limits
● Delay time
● Reverse connection protection
● Custom variable protection
● Overvoltage protection
● Overvcurrent protection
● Overtemperature protection
● Emergency stop protection
● Power down data protection
● Offline testing
● Voltage upper/lower limits
● Current upper/lower limits
● Delay time
● Reverse connection protection
● Overvoltage protection
● Overvcurrent protection
● Overtemperature protection
● Power down data protection
● Offline testing
● Voltage upper/lower limits
● Current upper/lower limits
● Delay time
● Reverse connection protection
● Overvoltage protection
● Overvcurrent protection
● Overtemperature protection
● Input over voltage protection
● Output overvoltage protection
● Input over current protection
● Output current protection
● Overheating protection
● Overload protection
● Output empty load protection
● Power down data protection
● Offline testing
● Reverse connection protection
● Voltage upper/lower limits
● Current upper/lower limits
● Delay time
● Capacity limits,
● Energy upper limit
● Control parameter out-of-tolerance protection
● Current/voltage fluctuation protection
● Voltage slope protection
● Delay protection
● Auxiliary voltage protection
● Auxiliary temperature protection
● Input over voltage protection
● Output overvoltage protection
● Input over current protection
● Output current protection
● Overheating protection
● Overload protection
● Output empty load protection
● Power down data protection
● Offline testing
● Security conditions seting
● Reverse connection protection
● Voltage upper/lower limits
● Current upper/lower limits
● Delay time
● Capacity limits
● Energy upper limit
● Control parameter out-of-tolerance protection
● Current/voltage fluctuation protection
● Voltage slope protection
● Delay protection
● Auxiliary voltage protection
● Auxiliary temperature protection

IP protection level

Protection level IP20
Protection level IP20
Protection level IP20
Protection level IP20
Protection level IP20

Channel characteristics

● Constant current source and constant voltage source adopt double closed-loop structure
● Constant current source and constant voltage source adopt double closed-loop structure
● Constant current source and constant voltage source adopt double closed-loop structure
● Constant current source and constant voltage source adopt double closed-loop structure
● Supports parallel connection of any adjacent channel
● Supports fault-tolerant operation (shielding fault channels)
● Energy Saving Inverter Technology, Energy flow locally between channels
● Adopt automotive main control scheme, 200kHz high-frequency conversion
● Low ripple noise, Small volume, Low energy consumption and heat production
● Constant current source and constant pressure source using independent double closed loop structure
● Integrated system design, the unit machine directly connects to the test server
● 100Hz high speed sampling
● 1GB offline storage capacity per channel
● Constant current source and constant voltage source adopt double closed-loop structure

Channel control mode

Individual control
Individual control
Individual control
Individual control
Individual control

Voltage and current detection sampling

Four wire connection
Four wire connection
Four wire connection
Four wire connection
Four wire connection

Noise level

<85dB
<75dB
<55dB
<45dB
<65dB
<75dB
<65dB
<75dB
<80dB
<85dB
<80dB

Database

Using MySQL database to manage test data
Using MySQL database to manage test data
Using MySQL database to manage test data
Using MySQL database to manage test data
Using MySQL database to manage test data

Communication mode of host computer

Based on TCP/IP protocols
Based on TCP/IP protocols
Based on TCP/IP protocols
Based on TCP/IP protocols
Based on TCP/IP protocols

Data transfer mode

Excel, Txt
Excel, Txt
Excel, Txt
NDA, Excel (customized export way of circulation layer, work layer, record layer, diagram, self- defined report), TXT, CSV
NDA, Excel (customized export way of circulation layer, work layer, record layer, diagram, self- defined report) , TXT, CSV

Server operating system

Windows 7, Windows10 or above
Windows 7, Windows10 or above
Windows 7, Windows10 or above
Windows 7, Windows10 or above
Windows 7, Windows10 or above

Communication interface

● Network interface
● Support CAN
● RS485 and BMS communication
● Support DBC configuration function (optional)
● Network interface
● Support CAN
● RS485 and BMS communication
● Support DBC configuration function (optional)
● Ethernet network
● Support CAN
● RS485 and BMS communication
● Support DBC configuration function (optional)
● Network interface
● Multiple machines extend communication through switches and routers (optional)
● Network interface

Working temperature

● 0℃ ~ 40℃ (in the range of 25±10℃, guaranteeing testing accurancy with fluctuation of 0.005% F.S. /℃)
● 0℃ ~ 40℃ (in the range of 25±10℃, guaranteeing testing accurancy with fluctuation of 0.005% F.S. /℃)
● -10℃ ~ 40℃ (in the range of 25±10℃, guaranteeing testing accurancy with fluctuation of 0.005% F.S. /℃)
● 25±10℃ / 25±5℃ (guaranteeing accurancy)
● 25±20℃ (limiting usage temperature)
● 25±5℃ (guaranteeing accurancy)
● 25±20℃ (limiting usage temperature)

Storage temperature

-10℃ ~ 50℃
-10℃ ~ 50℃
-20℃ ~ 50℃
0℃ ~ 45℃
0℃ ~ 60℃

Relative humidity range of the working environment

≤70% RH (No condensation)
≤70% RH (No condensation)
≤70% RH (No condensation)
30% ~ 80% RH (No condensation)
≤70% RH (No condensation)

Relative humidity range of the storage environment

≤80% RH (No condensation)
≤80% RH (No condensation)
≤80% RH (No condensation)
30% ~ 90% RH (No condensation)
≤80% RH (No condensation)

Note:Whether to support battery test with a protection plate

Not available when the voltage ≥20V
Not available when the voltage ≥20V
Not available
Available
Available

Battery Test Equipment

Here are some of our best-selling products, which can help you make a quick selection.
NEWARE-Battery Tester-CT-8002Q-5V100mA

Battery Test Equipment-NEWARE

CT-8002Q-5V100mA-124

CT-8000 Battery Testing System

● Voltage&Current Accuracy:±0.01% F.S.

● Recording Frequency:100Hz

● Current Response Time:≤1ms

● Minimum Pulse Width:500ms

● Off-Line Test:1GB/CH

● Cycle Life, GITT Test, DCIR Test, dQ/dV Curve

NEWARE-Battery Tester-CT-4008Q-5V100mA-124

Battery Test Equipment-NEWARE

CT-4008Q-5V100mA-124

CT-4000 Battery Testing System

● Voltage & Current Accuracy:±0.01% F.S.

● Recording Frequency:10Hz

● Sampling Time:100ms

● Current Response Time:≤1ms

● Minimum Pulse Width:500ms

● Off-Line Test: 1GB


CE-4008Q-5V15A-thumb

Battery Test Equipment-NEWARE

CE-4008Q-5V15A

CE-4000 Battery Testing System

● Voltage & Current Accuracy:±0.05% F.S.

● Recording Frequency:10Hz

● Sampling Time:100ms

● Current Response Time:≤1ms

● Energy Efficiency:>65%

● Off-Line Test: 1GB

Bttery test equipment-NEWARE-CE-4008Q-5V20A-Battery Testing System

Battery Test Equipment-NEWARE

CE-4008Q-5V20A

CE-4000 Battery Testing System

● Voltage & Current Accuracy:±0.05% F.S.

● Recording Frequency:10Hz

● Sampling Time:100ms

● Current Response Time:≤1ms

● Energy Efficiency:>65%

● Off-Line Test: 1GB

CE-4008Q-5V30A-thumb

Battery Test Equipment-NEWARE

CE-4008Q-5V30A

CE-4000 Battery Testing System

● Voltage & Current Accuracy:±0.05% F.S.

● Recording Frequency:10Hz

● Sampling Time:100ms

● Current Response Time:≤1ms

● Energy Efficiency:>65%

● Off-Line Test: 1GB

NEWARE-Battery Tester-CE-5012-5V600A

Battery Test Equipment-NEWARE

CE-5012-5V600A

CE-5000 Battery Testing System

● Voltage Accuracy:±0.02% F.S.

● Current Accuracy:±0.05% F.S.

● Resolution Ratio AD/DA:16bit

● Current Response Time:≤1ms

● Minimum Pulse Width:100ms

● Off-Line Test:1GB/CH

NEWARE-Battery Tester-CE-6000 Cell Testing System

Battery Test Equipment-NEWARE

CE-6000 Cell Testing System

● Voltage & Current Accuracy:±0.05% F.S.

● Recording Frequency:100Hz

● Current Conversion Time:≤6ms

● Current Response Time:≤3ms

● Minimum Pulse Width:100ms

● Feedback Efficiency (Max) :75%

NEWARE-Battery Teste-CT-9002-5V6A-F-204n

Battery Test Equipment-NEWARE

CT-9002-5V6A-F-204n

CT-9000 Battery Testing System

● Voltage & Current Accuracy:±0.02% F.S.

● Voltage & Current Stability:±0.01% F.S.

● Recording Frequency:1000Hz

● Resolution AD:16bit

● Current Response Time:≤100μs

● Off-Line Test: 1GB

Contact Us

Your comments are important to us, and we will address them as quickly as possible.
Name
Country
City Name
Company Name
Phone Number
Email Address *
Products
Model
Detailed Request
NEWARE and Cookies
We use Cookie to personalize and improve your experience with our website. By continuing to browse the site you are agreeing to our use of cookies.