HOME Smart Home Robot Vacuums

The evolution of batteries for home cleaning assistants.

The Evolution of Batteries for Home Cleaning Assistants

Impact of battery performance on ease of use of sweeping robots.

The battery is the power source of the sweeping robot, and its range directly affects the convenience of the robot. Currently, the capacity and energy density of the battery are important factors that limit the performance of sweeping robots. The energy density of the battery determines the single working time of the sweeping robot. Aging and performance decay of the battery are the main factors limiting its service life.

Test solutions to improve the performance of sweeping robot batteries.

NEWARE Battery Testing System has a low self-discharge test function that simulates long-term storage environments with different temperature and humidity conditions, accurately measuring the self-discharge rate of the sweeper's battery to ensure that the battery remains fully charged after a period of inactivity. At the same time, it supports BMS communication and can accurately monitor the voltage, current, temperature and status of the battery. Check if the system is able to adjust the charging strategy according to the battery status.

Safety and stability requirements for sweeping robot batteries.

Sweeping robot batteries must comply with safety standards such as IEC 62133-2, UL 2595 and UL 62133 to ensure that hazardous conditions such as overheating, short circuit or explosion do not occur during charging and use. The battery should have good stability and reliability to ensure that the robot maintains good performance after a long period of use.

Frame 427319777
NEWARE solution CT-4008Q-5V6A-S1-banner 1600
NEWARE solution CT-4008Q-5V6A-S1-banner web

Standard Testing

CT/CE-4/8000(3C)

NEWARE's CT/CE-4000 and CT/CE-8000 series for 3C battery testing system can provide the current and voltage ranges required for vacuum robot battery testing, with a variety of charging and discharging modes to meet battery testing needs, while focusing on user experience, featuring an intuitive operation interface and powerful data processing capabilities, making battery testing smooth and convenient. 


● Endurance test: simulate actual usage scenarios to test the battery life on the vacuum robot. 

● Multifunctional test: equipped with a variety of testing functions, it conducts charging and discharging cycle tests, constant current charging and discharging, constant voltage charging and discharging, internal resistance tests, etc., to deeply analyze battery performance and enhance the energy density and cycle stability of the battery. 

● Safety test: conduct overcharging, over-discharging, short circuit, and thermal stability tests on the product to assess the safety performance of the battery under extreme conditions, providing a basis for the safe design of the battery.

· Instruments

· Accessories

NEWARE-Battery Tester-CT-4000 Battery Testing System-ct4000-5v6-s1

CT-4008Q-5V6A-S1 *

CT-4000 Battery Testing System

● Voltage & Current Accuracy:±0.02% F.S.

● Recording Frequency:10Hz

● Sampling Time:100ms

● Current Response Time:≤1.5ms

● Minimum Pulse Width:500ms

● Off-Line Test:1GB

Read More
NEWARE-Battery Tester-CT-9000 Battery Testing System-ct4000-5v6-164

CT-4008Q-5V6A-164 *

CT-4000 Battery Testing System

● Voltage & Current Accuracy:±0.02% F.S.

● Recording Frequency:10Hz

● Sampling Time:100ms

● Current Response Time:≤1.5ms

● Minimum Pulse Width:500ms

● Off-Line Test:1GB

Read More
NEWARE-Battery Tester-CT-4000 Battery Testing System-5v12a-s1

CT-4008Q-5V12A-S1 *

CT-4000 Battery Testing System

● Voltage & Current Accuracy:±0.02% F.S.

● Recording Frequency:10Hz

● Sampling Time:100ms

● Current Response Time:≤1.5ms

● Minimum Pulse Width:500ms

● Off-Line Test:1GB

Read More
NEWARE-Battery Tester-CT-4000 Battery Testing System-5v12a-204-03

CT-4008Q-5V12A-204 *

CT-4000 Battery Testing System

● Voltage & Current Accuracy:±0.02% F.S.

● Recording Frequency:10Hz

● Sampling Time:100ms

● Current Response Time:≤1.5ms

● Minimum Pulse Width:500ms

● Off-Line Test:1GB

Read More
NEWARE-Battery Tester-CT-4000 Battery Testing System-5v15a

CE-4008Q-5V15A *

CE-4000 Battery Testing System

● Voltage & Current Accuracy:±0.05% F.S.

● Recording Frequency:10Hz

● Sampling Time:100ms

● Current Response Time:≤1ms

● Energy Efficiency:>65%

● Off-Line Test: 1GB

Read More
NEWARE-Battery Tester-CT-9000 Battery Testing System
NEWARE-Battery Tester-CT-9000 Battery Testing System

Ultra-High Precision Testing

CT-5000

CT-9000

Developed specifically for high-precision testing needs, it provides accurate and reliable test data, offering high-precision testing capabilities for batteries, accurately capturing subtle changes in the battery charging and discharging process at the microsecond level, thereby comprehensively evaluating the performance of the battery under different operating conditions. 


● High-precision testing: the multi-range design ensures the accuracy of the test, helping to solve problems such as battery performance degradation and life prediction. 

● Battery health assessment: it can help users assess the health of the vacuum robot battery by analyzing the designed capacity and the fully charged capacity, determining whether the battery needs to be replaced. 

● SMBus communication function: equipped with battery communication capabilities, it can monitor the status of the vacuum robot battery in real-time, providing immediate information.

· Instruments

· Accessories

NEWARE-Battery Tester-CT-9000 Battery Testing System-CT-9002-5V6A-F-204n

CT-9002-5V6A-F-204n *

CT-9000 Battery Testing System

● Voltage & Current Accuracy:±0.02% F.S.

● Voltage & Current Stability:±0.01% F.S.

● Recording Frequency:1000Hz

● Resolution AD:16bit

● Current Response Time:≤100μs

● Off-Line Test: 1GB

Read More
NEWARE-Battery Tester-CT-9000 Battery Testing System-CT-9040-5V5A-G4030

CT-9000-5V15A *

CT-9000 Battery Testing System

● Voltage & Current Accuracy:±0.02% F.S.

● Recording Frequency:1000Hz

● Resolution AD:16bit

● Current Response Time:≤150μs

● Off-Line Test:1GB

Read More
NEWARE-Battery Tester-CT-5000 Battery Testing System-CT-5080-5V6A

CT-5080-5V6A *

CT-5000 Battery Testing System

● Voltage & Current Accuracy:±0.02% F.S.

● Recording Frequency:100Hz

● Resolution Ratio AD/DA:16bit

● Current Response Time:≤2ms

● Single-Cycle Operation Count:255 cycles

● Off-Line Test:1GB/CH

Read More
NEWARE solution WHW-500L-5V6A80CH-380V-banner 1600
NEWARE solution WHW-500L-5V6A80CH-380V-banner web

​Integrated Temperature Control Testing

All-in-One Testing System

The integrated charging and discharging testing system with environmental testing provides a constant temperature environment or high and low temperature environments for battery testing, simulating the use of vacuum robots in daily home environments to ensure the stability and reliability of the batteries. 


● Simulate high and low temperature environments: assess the adaptability and durability of the battery under extreme temperature changes, which is essential to ensure that the vacuum robot can work properly in different seasons and regions. 

● Improve space utilization: the internal space of the integrated machine can be specified to meet the needs of batch battery testing, with a single device capable of performing a variety of tests.

· Instruments

· Accessories

NEWARE-Battery Tester-WHW-500L-5V6A80CH-380V

WHW-500L-5V6A80CH-380V *

3C All-in-One Testing System

● Voltage & Current Accuracy:±0.05% F.S.

● Recording Frequency:100Hz

● Number of Channels:80CH

● Temperature Range & Deviation:50℉ ~ 185℉±3.6℉(10℃ ~ 85℃±2.0℃)

● Heating Efficiency:77℉ ~ 185℉ ≤40min(25℃ ~ 85℃)

● Cooling Efficiency:77℉ ~ 50℉≤40min(25℃~10 ℃)

Read More

Accessory Equipment

Contact Us

For more product details, please contact the sales specialist on the right or provide your contact information in the form below. You can also to contact your local distributor for more information.
Name
Country
City Name
Company Name
Phone Number
Email Address *
Products
Model
Detailed Request
NEWARE and Cookies
We use Cookie to personalize and improve your experience with our website. By continuing to browse the site you are agreeing to our use of cookies.