AI
Store
Newell
Contact
Language
US/English
CN/中文
KR/한국어
JP/日本語
Battery Testing System
|
Formation and Grading System
|
AI Lab System
Language
US/English
CN/中文
JP/日本語
KR/한국어
Products
Battery Test Equipment
CT/CE-4000 Series
CT/CE-8000 Series
CE-6000 Series
CT/CE-5000 Series
CT/CE-9000 Series
Accessories
Probes
Test Lines
Coin Cell Fixtures
Pouch Cell Fixtures
Cylindrical Cell Fixtures
Prismatic Cell Fixtures
Pressure Plate Clamps
Battery Materials
Environmental Test Chambers
All-in-One Battery Testing System
Constant Temperature Chamber
High and Low Temperature Chamber
Explosion-Proof Chamber
Safety Test Equipment
Automatic Production
Pouch Cell Automation
Cylindrical Cell Automation
Prismatic Cell Automation
Auxiliary Modules
Control Unit
Auxiliary Channel
Calibration
Voltmeter
Ammeter
BVIR
EOL
EIS
Software
BTS 8.1
BTS 9.1
Tool Software
Solutions
Main Applications
3C Electronic Products
Cell Phone Battery
Laptop and Tablet Battery
Bluetooth Headphone
Transportation
Electric Vehicle Battery
Electric Transportation Battery
Energy Storage
Electric Energy Storage
Communication Energy Storage
User-Side Energy Storage
AI Laboratories
Coin Cell Experimental Line
Pouch Cell Experimental Line
Cylindrical Cell Experimental Line
Commercial Applications
Battery Research
Battery Materials Research
Solid-State Battery Research
Electric Vehicles Parameter Assessment
Electric Tools
Household Electric Tools
lndustrial Electric Tools
Intelligent Robots
Industrial Robots
Service Robots
Medical Care Devices
Household Devices
Professional Hospital Devices
Safety Protection
Monitor & Alarm System
lntelligent Recognition
Smart City
Bicycle-Sharing
Smart Street Lights
Measuring Meters
Smart Electricity Meters
Smart Water & Gas Meters
Personal Care Devices
Electric Toothbrushes
Electric Razors
Support
FAQ
Compare Models
Software
Hardware
Glossary
Hardware
Software
Battery Manufacturing Terminology
BTS Tutorial
BTS 8.0
BTS 9.0
BTSDA
Manuals & Documentation
Specifications
Catalogs
Quick Start Guide
CT/CE-4000 Series
CE-6000 Series
Environmental Test Chambers
Battery Experimental Line
Services
Sales Team
Warranty Request
About Us
Who We Are
What We Do
Contact Us
Events
News
LabTech
Store
Newell
Contact
NEWARE battery tester software glossary-Battery test
Software
NEWARE technologies learning center
HOME
Glossary
Software
Glossary
Hardware
Battery Test Equipments
Environmental Test Chambers
Automatic Production
Accessories
Auxiliary Modules
Others
Software
BTS
BTSDA
Others
Battery Manufacturing Terminology
Basic Terminology
Battery Product Terminology
Manufacturing Process Terminology
Manufacturing Equipment Terminology
Manufacturing Quality Management Terminology
Manufacturing Environment Terminology
Smart Manufacturing Terminology
Safety Terminology
Hardware Module
Product Features
Product Parameters
Filter
Recording condition
Conditions for data recording.
Subsection record
According to certain conditions, the recording conditions are set separately.
Cyclic accumulation
The capacity of the same step will be accumulated.
Automatic backup
The software/system saves the tested data into a specified directory automatically according to the set conditions.
Fading rate
The discharge capacity of a certain cycle is set as the standard, and the decay rate is obtained by comparing each subsequent cycle with the standard cycle.
Copy channel
Copy the steps of one channel to other channels.
Channel information
The details of the selected channel.
Battery internal resistance
The resistance of the battery itself.
Capacity accumulation
Accumulate the capacity of continuous charge or discharge (exclude rest step) steps.
Nominal capacity
The released capacity of a battery when it is discharged from full state to the termination voltage.
Nominal specific capacity
The nominal capacity per unit mass/volume.
Depth of discharge (DOD)
The percentage of released capacity by the battery to its rated capacity.
State of charge (SOC)
It is used to reflect the current capacity of the battery and can be expressed as percentage ratio of the current capacity and rated capacity
Plateau capacity
The corresponding capacity value when the voltage reaches the set plateau voltage.
Plateau time
The corresponding time when the voltage reaches the set plateau voltage.
Active material
The cathode/anode material, which attends the current formation reaction (electrochemical reaction process).
Current upper limit
The channel will be protected when the current of the present step is greater than or equal to the set value
Current lower limit
The channel will be protected when the current of the present step is less than or equal to the set value.
Voltage upper limit
The channel will be protected when the present step voltage is greater than or equal to the value set by the upper voltage limit.
Voltage lower limit
The channel will be protected when the present step voltage is less than or equal to the value set by the upper voltage limit.
Press upper limit
The channel will be protected when the press of the present step is greater than or equal to the set value.
Press lower limit
The channel will be protected when the press of the present step is less than or equal to the set value.
Capacity upper limit protection
The channel will be protected when the capacity of the present step is greater than or equal to the set value.
Expression
A formula consisting of numbers, operators, and variables.
first
previous
3
4
5
6
7
8
9
10
11
next
Read More
NEWARE and Cookies
We use Cookie to personalize and improve your experience with our website. By continuing to browse the site you are agreeing to our use of cookies.
Accept